Menu

BOSCH REXROTH SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1

Quantity:
Brand: BOSCH REXROTH
SKU:{{ product.sku }}
Name:BOSCH REXROTH SYDFEE2X140RPPB12KD30487A0A0EX1
PN/Model:SYDFEE2X140RPPB12KD30487A0A0EX1
Condition:Brand new
Warranty:12 months

REQUEST A QUOTE: sales@globalpartsservice.com

Model: {{ product.model }}

{{ variable.name }}

{{ value.name }}

 

The Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 is a digital servo valve designed by Bosch Rexroth AG, a German company specializing in industrial automation and motion控制 technologies. The "SYDFEE" product line specifically covers high-performance electronic directionals including servovalves, proportional valves, and other related components.

 

This particular valve belongs to the D*SERT, which stands for Digital Servo Valve EXtendable R e m o v e r T itle. The Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 is primarily intended as a proportional directional valve for mobile and stationary equipment in various industrial applications requiring precise control of fluids, such as construction machines, agricultural vehicles, and materials handling equipment.

 

Features of this servo valve include:

 

Fully integrated position feedback system capable of high-resolution signal processing

 

Integrated holding brake and stroke monitoring functions

 

Robust aluminum body with protection level IP65 rated against dust and splash water

 

Comprehensive diagnostics capabilities via LED status indicators and programmable alarm outputs

 

Extensible software architecture with configurable operating parameters

 

Compatibility across multiple industry-standard control protocols

 

In terms of specifications, the Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 operates on conventional DC voltage supplies between 12V and 24V input ranges, consuming a maximum of 70 watts while delivering up to 40 l/min flow rates under pressures reaching 210 bar. Like most modern hydraulic valves, this servo valve also offers convenient integration into automated manufacturing processes through protocols like CANopen or EtherCAT, enabling seamless incorporation into larger-scale roboticized or platenform manufacturing operations.

 

Overall, the Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 serves as a highly advanced, feature-rich solution for precision fluid power control in a wide range of industrial applications emphasizing accuracy, repeatability, and robustness.

 

mechanic and hydraulic

Size

18 28 45 71 100 140

Displacement

Vg max

cm³

18 28 45 71 100 140

Speed 1)

maximum at Vg max

nnom

rpm

3300 3000 2600 2200 2000 1800

maximum at Vg < Vg max

nmax zul

rpm

3900 3600 3100 2600 2400 2100

Minimum speed

nmin

rpm

50

Max. flow (displacement)

at nnom and Vg max

qV max

l/min

59.4 84 117 156 200 252

with nE = 1500 rpm and Vg max

qvE max

l/min

27 42 68 107 150 210

Max. power (Δp = 280 bar)

at nnom and Vg max

P max

kW

27.7 39 55 73 93 118

with nE = 1500 rpm and Vg max

PE max

kW

12.6 20 32 50 70 98

Max. torque (Δp = 280 bar)

Tmax

Nm

80.1 125 200 316 445 623

Maximum permissible drive torque

Fitting key

Ttotal

Nm

88 137 200 439 857 1206

Splined shaft S overall torque

Ttotal

Nm

124 - 1104 1620

Max. admissible through-drive torque

TD

Nm

108 - 778 1266

Splined shaft R overall torque

Ttotal

Nm

- 225 400 644 -

Max. admissible through-drive torque

TD

Nm

- 176 365 548 -

Drive shaft load

technical illustration-SYDFEE-2X/140R-PSB12KD3-0000-A0A1VXX-SYDFEE-2X

max. admissible axial force

Fax max

N

700 1000 1500 2400 4000 4800

max. admissible radial force

Fq

N 2)

350 1200 1500 1900 2300 2800

Mass

Pump without through-drive incl. pilot valve

m

kg

14 17 23 35 47 62

in addition, preload valve

m

kg

3.3 6.3

in addition, in case of external supply

m

kg

2

Moment of inertia around drive axis

kg·m²

0.0009 0.0017 0.0033 0.0083 0.0167 0.0242

Filling quantity of the housing

l

0.4 0.7 1 1.6 2.2 3

Maximum admissible operating pressure

pmax

bar

280 3) 280

Operating pressure, min. (without load)

with preload valve

pmin

bar

≥ 1

without preload valve

pmin

bar

≥ 20

in case of external supply (20 bar) 4)

pmin

bar

> 10

Admissible inlet pressure

p

bar

0.8 ... 10

Hydraulic fluid

  Mineral oil (HL, HLP) to DIN 51524

Hydraulic fluid temperature range

ϑ

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406

  Class 18/16/13 (for particle size ≤ 4/6/14 μm)
1) The values are applicable at an absolute pressure of 1 bar at the suction opening S. With a reduction of the displacement or an increase in the inlet pressure, the speed can be increased according to the following characteristic curve. With a reduced inlet pressure, the speed is to be reduced.
2) In case of higher radial forces, please consult us
3) In case of higher pressures, please consult us
4) In continuous operation; in case of operation below 10 bar, observe the notes

elektrisch

Size

18 28 45 71 100 140

Operating voltage

UB

  24 +40 % –5 %

Operating range (short-time operation)

Upper limit value

UB(t)max

V

35

Lower limit value

UB(t)min

V

21

Current consumption (in static control operation)

Rated current

Inom

A

0.6

Maximum current

Imax

A

1.25

Inputs

Actual pressure value input X1;
pin 10 and 11

U or I

  Determination by means of ordering code

Analog current inputs, load 1)

RB

  100 Ω

Analog voltage inputs

RE

  ≥ 50 kΩ

Digital inputs

Logic 0

  ≤ 0,6 V

Logic 1

  ≥ 21 V

Outputs

pactual / UOUT1

UO

  0 ... 10 V

Imax

1,5 mA

αactual / UOUT2

UO

  ± 10 V

Imax

1,5 mA

Digital outputs

Logic 0

  Ua < 1 V

Logic 1

  Ua ≥ UB – 5 V; 10 mA (short-circuit-proof)

Ambient temperature range at the pump

ϑ

°C

​0 … ​60

Storage temperature range (pump + electronics)

ϑ

°C

​0 … ​70

Electronics design

  Integrated in the pilot valve (OBE)

Type of protection according to EN 60529

Pump incl. pilot valve

  IP65 with mounted and locked plug-in connectors
1) With configuration on current input: Maximum admissible input current 30 mA
2) With SYDFEC, SYDFEn and SYDFED, the outputs are parameterizable, for the condition as supplied, see electrical connection.

Notice:

For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.

 

Control loop quality

Notes:

The specified values are only valid when using the system-related components specified in this data sheet. At pressures < 20 bar, higher tolerances have to be anticipated due to lower actuating forces.

 

Swivel angle control

Pressure control

1)

Linearity tolerance

≤ 1.0 %

≤ 1.5 % (≤ 1.0 %)

Temperature error

≤ 0.5 % / 10 K

≤ 0.5 % / 10 K

Hysteresis

≤ 0.2 %

≤ 0.2 %

Repetition accuracy

≤ 0.2 %

≤ 0.2 %

1) Without considering the pump pulsation.