The Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 is a digital servo valve designed by Bosch Rexroth AG, a German company specializing in industrial automation and motion控制 technologies. The "SYDFEE" product line specifically covers high-performance electronic directionals including servovalves, proportional valves, and other related components.
This particular valve belongs to the D*SERT, which stands for Digital Servo Valve EXtendable R e m o v e r T itle. The Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 is primarily intended as a proportional directional valve for mobile and stationary equipment in various industrial applications requiring precise control of fluids, such as construction machines, agricultural vehicles, and materials handling equipment.
Features of this servo valve include:
Fully integrated position feedback system capable of high-resolution signal processing
Integrated holding brake and stroke monitoring functions
Robust aluminum body with protection level IP65 rated against dust and splash water
Comprehensive diagnostics capabilities via LED status indicators and programmable alarm outputs
Extensible software architecture with configurable operating parameters
Compatibility across multiple industry-standard control protocols
In terms of specifications, the Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 operates on conventional DC voltage supplies between 12V and 24V input ranges, consuming a maximum of 70 watts while delivering up to 40 l/min flow rates under pressures reaching 210 bar. Like most modern hydraulic valves, this servo valve also offers convenient integration into automated manufacturing processes through protocols like CANopen or EtherCAT, enabling seamless incorporation into larger-scale roboticized or platenform manufacturing operations.
Overall, the Bosch Rexorth SYDFEE-2X/140R-PPB12KD3-0487-A0A0EX1 serves as a highly advanced, feature-rich solution for precision fluid power control in a wide range of industrial applications emphasizing accuracy, repeatability, and robustness.
Size |
18 | 28 | 45 | 71 | 100 | 140 | ||||
Displacement |
Vg max |
cm³ |
18 | 28 | 45 | 71 | 100 | 140 | ||
Speed 1) |
maximum at Vg max |
nnom |
rpm |
3300 | 3000 | 2600 | 2200 | 2000 | 1800 | |
maximum at Vg < Vg max |
nmax zul |
rpm |
3900 | 3600 | 3100 | 2600 | 2400 | 2100 | ||
Minimum speed |
nmin |
rpm |
50 | |||||||
Max. flow (displacement) |
at nnom and Vg max |
qV max |
l/min |
59.4 | 84 | 117 | 156 | 200 | 252 | |
with nE = 1500 rpm and Vg max |
qvE max |
l/min |
27 | 42 | 68 | 107 | 150 | 210 | ||
Max. power (Δp = 280 bar) |
at nnom and Vg max |
P max |
kW |
27.7 | 39 | 55 | 73 | 93 | 118 | |
with nE = 1500 rpm and Vg max |
PE max |
kW |
12.6 | 20 | 32 | 50 | 70 | 98 | ||
Max. torque (Δp = 280 bar) |
Tmax |
Nm |
80.1 | 125 | 200 | 316 | 445 | 623 | ||
Maximum permissible drive torque |
Fitting key |
Ttotal |
Nm |
88 | 137 | 200 | 439 | 857 | 1206 | |
Splined shaft S overall torque |
Ttotal |
Nm |
124 | - | 1104 | 1620 | ||||
Max. admissible through-drive torque |
TD |
Nm |
108 | - | 778 | 1266 | ||||
Splined shaft R overall torque |
Ttotal |
Nm |
- | 225 | 400 | 644 | - | |||
Max. admissible through-drive torque |
TD |
Nm |
- | 176 | 365 | 548 | - | |||
Drive shaft load |
max. admissible axial force |
Fax max |
N |
700 | 1000 | 1500 | 2400 | 4000 | 4800 | |
max. admissible radial force |
Fq |
N 2) |
350 | 1200 | 1500 | 1900 | 2300 | 2800 | ||
Mass |
Pump without through-drive incl. pilot valve |
m |
kg |
14 | 17 | 23 | 35 | 47 | 62 | |
in addition, preload valve |
m |
kg |
3.3 | 6.3 | ||||||
in addition, in case of external supply |
m |
kg |
2 | |||||||
Moment of inertia around drive axis |
kg·m² |
0.0009 | 0.0017 | 0.0033 | 0.0083 | 0.0167 | 0.0242 | |||
Filling quantity of the housing |
l |
0.4 | 0.7 | 1 | 1.6 | 2.2 | 3 | |||
Maximum admissible operating pressure |
pmax |
bar |
280 3) | 280 | ||||||
Operating pressure, min. (without load) |
with preload valve |
pmin |
bar |
≥ 1 | ||||||
without preload valve |
pmin |
bar |
≥ 20 | |||||||
in case of external supply (20 bar) 4) |
pmin |
bar |
> 10 | |||||||
Admissible inlet pressure |
p |
bar |
0.8 ... 10 | |||||||
Hydraulic fluid |
Mineral oil (HL, HLP) to DIN 51524 | |||||||||
Hydraulic fluid temperature range |
ϑ |
°C |
-20 … +70 | |||||||
Maximum admissible degree of contamination of the hydraulic fluid according to ISO 4406 |
Class 18/16/13 (for particle size ≤ 4/6/14 μm) |
1) | The values are applicable at an absolute pressure of 1 bar at the suction opening S. With a reduction of the displacement or an increase in the inlet pressure, the speed can be increased according to the following characteristic curve. With a reduced inlet pressure, the speed is to be reduced. |
2) | In case of higher radial forces, please consult us |
3) | In case of higher pressures, please consult us |
4) | In continuous operation; in case of operation below 10 bar, observe the notes |
Size |
18 | 28 | 45 | 71 | 100 | 140 | |||
Operating voltage |
UB |
24 +40 % –5 % | |||||||
Operating range (short-time operation) |
Upper limit value |
UB(t)max |
V |
35 | |||||
Lower limit value |
UB(t)min |
V |
21 | ||||||
Current consumption (in static control operation) |
Rated current |
Inom |
A |
0.6 | |||||
Maximum current |
Imax |
A |
1.25 | ||||||
Inputs |
Actual pressure value input X1; |
U or I |
Determination by means of ordering code | ||||||
Analog current inputs, load 1) |
RB |
100 Ω | |||||||
Analog voltage inputs |
RE |
≥ 50 kΩ | |||||||
Digital inputs |
Logic 0 |
≤ 0,6 V | |||||||
Logic 1 |
≥ 21 V | ||||||||
Outputs |
pactual / UOUT1 |
UO |
0 ... 10 V | ||||||
Imax |
1,5 mA | ||||||||
αactual / UOUT2 |
UO |
± 10 V | |||||||
Imax |
1,5 mA | ||||||||
Digital outputs |
Logic 0 |
Ua < 1 V | |||||||
Logic 1 |
Ua ≥ UB – 5 V; 10 mA (short-circuit-proof) | ||||||||
Ambient temperature range at the pump |
ϑ |
°C |
0 … 60 | ||||||
Storage temperature range (pump + electronics) |
ϑ |
°C |
0 … 70 | ||||||
Electronics design |
Integrated in the pilot valve (OBE) | ||||||||
Type of protection according to EN 60529 |
Pump incl. pilot valve |
IP65 with mounted and locked plug-in connectors |
1) | With configuration on current input: Maximum admissible input current 30 mA |
2) | With SYDFEC, SYDFEn and SYDFED, the outputs are parameterizable, for the condition as supplied, see electrical connection. |
Notice:
For information on the environment simulation testing for the areas of EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30030-U.
Notes:
The specified values are only valid when using the system-related components specified in this data sheet. At pressures < 20 bar, higher tolerances have to be anticipated due to lower actuating forces.
Swivel angle control |
Pressure control 1) |
|
Linearity tolerance |
≤ 1.0 % |
≤ 1.5 % (≤ 1.0 %) |
Temperature error |
≤ 0.5 % / 10 K |
≤ 0.5 % / 10 K |
Hysteresis |
≤ 0.2 % |
≤ 0.2 % |
Repetition accuracy |
≤ 0.2 % |
≤ 0.2 % |
1) | Without considering the pump pulsation. |
For applications outside these parameters, please consult us!